Results meeting the search terms "https//dailygummycbd.com/en-us/power-cbd-gummy-bears"
![105TX N-Tron Industrial Ethernet Switch 5 Port Unmanaged [105TX]](images/products/105tx.jpg)
N-Tron 105TX 5 Port 10/100BaseTX Industrial Ethernet Switch. Compact Size, Small Footprint. Full IEEE 802.3 Compliance. Rugged Metal DIN-Rail Enclosure. 10-30VDC Power Input. …
https://www.controlcomponentsinc.com/105tx-n-tron-industrial-ethernet-switch-5-port-unmanaged-p-1929.html
![KFD2-ELD-Ex16 Pepperl Fuchs Switch Amplifier [KFD2-ELD-Ex16]](images/KFD2-ELD-Ex16.png)
16-channel isolated barrier, 24 V DC supply (Power Rail), Analog or digtial field device inputs, Monitors leakage current, Fault relay contact output, LED status indication, Test circuit for validation, Parallel connection for easy integration, Conformal coating …
https://www.controlcomponentsinc.com/kfd2-eld-ex16-pepperl-fuchs-switch-amplifier-p-5434.html
![KFD2-ST3-Ex1.LB Pepperl Fuchs Switch Amplifier [KFD2-ST3-Ex1.LB]](images/KFD2-SR3-Ex2.2S.png)
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 active transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508 …
https://www.controlcomponentsinc.com/kfd2-st3-ex1lb-pepperl-fuchs-switch-amplifier-p-5423.html
![Pepperl+Fuchs KCD2-UT2-Ex1 Universal Temperature Converter [KCD2-UT2-Ex1]](images/KCD2-UT2-Ex1.png)
1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Current output 0/4 mA ... 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511 …
https://www.controlcomponentsinc.com/pepperlfuchs-kcd2-ut2-ex1-universal-temperature-converter-p-5455.html
![Pepperl+Fuchs KFD2-UT2-Ex1 Universal Temperature Converter [KFD2-UT2-Ex1]](images/KFD2-PT2-Ex1-1.png)
1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Current output 0/4 mA ... 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511 …
https://www.controlcomponentsinc.com/pepperlfuchs-kfd2-ut2-ex1-universal-temperature-converter-p-5460.html
![KFD2-DU-Ex1.D Pepperl Fuchs Switch Amplifier [KFD2-DU-Ex1.D]](images/KFD2-DU-Ex1.D img.png)
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact and transistor output, Adjustable output timer functions from 10 ms ... 60 min, Input frequency up to 80 Hz; pulse divider up to 1 kHz, Reset function, Configurable by keypad, Line fault detection (LFD) …
https://www.controlcomponentsinc.com/kfd2-du-ex1d-pepperl-fuchs-switch-amplifier-p-5408.html
![KCD2-SR-Ex2.SP Pepperl Fuchs Switch Amplifier [KCD2-SR-Ex2.SP]](images/KCD2-SR-Ex2.SP img.png)
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Relay contact output, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508 …
https://www.controlcomponentsinc.com/kcd2-sr-ex2sp-pepperl-fuchs-switch-amplifier-p-5419.html
![KFD2-SR2-Ex2.2S Pepperl Fuchs Switch Amplifier [KFD2-SR2-Ex2.2S]](images/KFD2-SR2-Ex2.W.png)
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), 2 x 2 relay contact outputs with AND logic, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508 …
https://www.controlcomponentsinc.com/kfd2-sr2-ex22s-pepperl-fuchs-switch-amplifier-p-5442.html
![KFD2-SR3-Ex2.2S Pepperl Fuchs Switch Amplifier [KFD2-SR3-Ex2.2S]](images/KFD2-SR3-Ex2.2S.png)
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Usable as signal splitter (1 input and 2 outputs), 2 x 2 relay contact outputs with AND logic, Reversible mode of operation, Line fault detection (LFD), Up to SIL 2 acc. to IEC 61508 …
https://www.controlcomponentsinc.com/kfd2-sr3-ex22s-pepperl-fuchs-switch-amplifier-p-5436.html
![Pepperl+Fuchs KFD2-UT2-Ex2-1 Universal Temperature Converter [KFD2-UT2-Ex2-1]](images/KFD2-UT2-Ex2-1.png)
2-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Usable as signal splitter (1 input and 2 outputs), Voltage output 0/1 V ... 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511 …
https://www.controlcomponentsinc.com/pepperlfuchs-kfd2-ut2-ex2-1-universal-temperature-converter-p-5464.html
![KCD2-SOT-Ex2.SP Pepperl Fuchs Switch Amplifier [KCD2-SOT-Ex2.SP]](images/KCD2-SOT-Ex1.LB.png)
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508 …
https://www.controlcomponentsinc.com/kcd2-sot-ex2sp-pepperl-fuchs-switch-amplifier-p-5416.html
![KCD2-SON-Ex2.SP Pepperl Fuchs Switch Amplifier [KCD2-SON-Ex2.SP]](images/KFD2-ER-Ex1.W.LB img.png)
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs (resistive acc. to EN 60947-5-6), Line fault transparency (LFT), Housing width 12.5 mm, Connection via spring terminals with push-in connection technology, Up to SIL 2 acc. to IEC 61508 …
https://www.controlcomponentsinc.com/kcd2-son-ex2sp-pepperl-fuchs-switch-amplifier-p-5415.html
![KCD2-SOT-Ex1.LB Pepperl Fuchs Switch Amplifier [KCD2-SOT-Ex1.LB]](images/KCD2-SOT-Ex1.LB.png)
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508 …
https://www.controlcomponentsinc.com/kcd2-sot-ex1lb-pepperl-fuchs-switch-amplifier-p-5418.html
![KCD2-ST-Ex1.LB Pepperl Fuchs Switch Amplifier [KCD2-ST-Ex1.LB]](images/KCD2-SOT-Ex1.LB.png)
1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 active transistor outputs, Usable as signal splitter (1 input and 2 outputs), Reversible mode of operation, Line fault detection (LFD), Housing width 12.5 mm, Up to SIL 2 acc. to IEC 61508 …
https://www.controlcomponentsinc.com/kcd2-st-ex1lb-pepperl-fuchs-switch-amplifier-p-5428.html
![KFD2-SOT2-Ex2.IO Pepperl Fuchs Switch Amplifier [KFD2-SOT2-Ex2.IO]](images/KFD2-SOT2-Ex2.IO.png)
2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Isolated passive transistor output, non-polarized, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC 61508 …
https://www.controlcomponentsinc.com/kfd2-sot2-ex2io-pepperl-fuchs-switch-amplifier-p-5440.html
![Pepperl+Fuchs Z961.H Din Mount Zener Barrier [Z961.H]](images/products/pf_zenbarrier.jpg)
2-channel, AC version, Working voltage 6.5 V at 10 A, Series resistance max. 380 , Fuse rating 50 mA, DIN rail mounting, High power version, Number of channels: 2-channel …
https://www.controlcomponentsinc.com/pepperlfuchs-z961h-din-mount-zener-barrier-p-3319.html
![Pepperl+Fuchs Z966.H Din Mount Zener Barrier [Z966.H]](images/products/pf_zenbarrier.jpg)
2-channel, AC version, Working voltage 10 V at 10 A, Series resistance max. 82 , Fuse rating 100 mA, DIN rail mounting, High power version, Number of channels: 2-channel …
https://www.controlcomponentsinc.com/pepperlfuchs-z966h-din-mount-zener-barrier-p-3324.html
![Pepperl+Fuchs KFD2-GUT-Ex1.D Temperature Converter [KFD2-GUT-Ex1.D]](images/KFD2-GUT-Ex1.D.png)
1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Redundant TC input, Current output 0/4 mA ... 20 mA, 2 relay contact outputs, Configurable by PACTware or keypad, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511 …
https://www.controlcomponentsinc.com/pepperlfuchs-kfd2-gut-ex1d-temperature-converter-p-5458.html
![Pepperl+Fuchs Z728.H Din Mount Zener Barrier [Z728.H]](images/products/pf_zenbarrier.jpg)
1-channel, DC version, positive polarity, Working voltage 26.5 V at 10 A, Series resistance max. 250 , Fuse rating 80 mA, DIN rail mounting, High power version, Number of channels: 1-channel …
https://www.controlcomponentsinc.com/pepperlfuchs-z728h-din-mount-zener-barrier-p-3273.html
![Pepperl+Fuchs Z779.H Din Mount Zener Barrier [Z779.H]](images/products/pf_zenbarrier.jpg)
2-channel, DC version, positive polarity, Working voltage 26.5 V at 10 A, Series resistance max. 250 , Fuse rating 80 mA, DIN rail mounting, High power version, Number of channels: 2-channel …
https://www.controlcomponentsinc.com/pepperlfuchs-z779h-din-mount-zener-barrier-p-3284.html